( ! ) Warning: mysqli::__construct(): (HY000/1040): Too many connections in /usr/lib/php/connect_bizpage_slave_mysqli.php on line 2
Call Stack
#TimeMemoryFunctionLocation
10.0026773864{main}( ).../index.php:0
20.0028787168require_once( '/home/indianyp/indianyellowpages.com/htdocs/bizpage/config-mysqli.php' ).../index.php:10
30.0028788800require( '/usr/lib/php/connect_bizpage_slave_mysqli.php' ).../config-mysqli.php:3
40.0028789184__construct ( ).../connect_bizpage_slave_mysqli.php:2
Electrosurgical Unit-Advin Electro+ Surgical Generator Exporter, Supplier from Ahmedabad

Electrosurgical Unit-Advin Electro+ Surgical Generator



We make sure that the packing of our products is done using quality materials and advanced machines. Our packaging experts handle the entire task of packaging keeping in mind the requirements of the clients. Supplying from our facility in Ahmedabad(India), our organizations is a well-reckoned provider in the market.

Electrosurgical Unit-Advin Electro+ Details :

  • Our new Advin Electro+ is the most versatile Electro Surgical Generator. It offers features and performance never before available in a single generator. The Advin Electro+ has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
  • The blend gives a good Hemostasis effect than cutting and pure cut is exceptionally smooth and starts promptly even in irrigated procedures. The isolated bipolar output, which has a non-sparking characteristic, is ideal for microsurgery, Neuro Surgery, Laproscopy and other applications.
  • Advin Electro+ meets the surgeons needs in the wide range of general procedures and in specialties including Gynecology, Urology, Neurology, Thorasic, Plastic and Reconstructive Surgery.


Features :

  • Four modes In Cut - Pure Cut  A high-frequency alternating current yields smooth, rapid cuts that evoke little to no hemostasis. Blend 1  Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode. Blend 2  The mode is used for the vaporization of prostatic tissue or any fat tissue.
  • The higher output wattage gives fast cutting effect of the tissue. Endocut  The mode is used to automatically control cut system to reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode.


Four modes In Coag :

  • Spray Spray output is made for direct coagulation at the tissue with spark. Above spark does not give any cutting effect as its CREST FACTOR is high.
  • Force  Pure coagulation.
  • Fulgurate  Sparking the tissue to lead to coagulation.
  • There is no tissueelectrod


Technical Specification

Cut
Mode Max power Load Creast Factor
Pure cut 400W 500E 1.5
Blend 1 250W 500E 1.5
Blend 2 200W 500E 1.5
Endocut 0.99 500E 1.5
Coag
Mode Max power Load Creast Factor
Spray 120W 500E 7
Force 120W 500E 6.5
Fulgurate 150W 500E 6
Desiccate 150W 500E 6
Bipolar Mode
Mode Max power Load Creast Factor
Micro sow 100E 1.5
Macro sow 100E 1.5
Cut 100W 100E 1.5
Auto 100W 100E 1.5